Skip to content Skip to a section

🏠Measured properties

Gypsum board · CaSO4·2H2O panels that buy fire time by calcining — the everyday A2/A1 lining of interiors.

At a glance
Score intensity

Darker cells mean a higher score for this topic on that metric.

Last reviewed Sources & creditsMedia creditsMethodology

Quick answers

Is Gypsum board non-combustible?

Declared reaction class in this atlas: A2-s1,d0 typical; core A1. Assemblies still need resistance tests.

Does Gypsum board insulate?

Thermal mark 34/100 versus the atlas. Conductivity note: ~0.17 W/m·K.

What is the density band?

~700–1000 kg/m³

How is it made?

Origin story: Sackett 1894; US Gypsum 1916 (United States).

Can it be recycled?

Circularity mark 62/100 — editorial, route-specific.

Typical melting or failure heat?

calcines ~80–180 °C (dehydration)

heat 54 · fire 92

Start with this section - Measured properties

Numbers below are bands used by working engineers, not live quotes. Tensile note: paper faces take bending; wet boards are scrap.

Fire performance in this atlas is editorial. Real projects need the assembly report.

Mechanical

Strength band

paper faces take bending; wet boards are scrap

Stiffness

Modulus follows chemistry and orientation — not the marketing nickname.

Toughness

Crack growth, not peak stress, retires most real parts.

Fatigue / creep

Cyclic and time-dependent damage dominate certificates issued on static coupons.

Hardness / hand

Indentation, drape or compressive class — whichever the trade actually measures.

Thermal

Conductivity

~0.17 W/m·K — Gypsum board is not a substitute for a dedicated λ layer.

Service temperature

Melting / softening / decomposition band: calcines ~80–180 °C (dehydration).

Expansion

Joints and clearances must follow the expansion class of Gypsum board, not of steel-by-habit.

Thermal mass

Density ~700–1000 kg/m³ sets how fast a section changes temperature.

Ageing of λ

Foams, VIPs and moist batts drift; quote aged values.

Electrical

Conductor or dielectric

Gypsum board is generally a dielectric or semiconductor film, not building wire.

Static / EMI

Fillers and moisture change resistivity more than brochures admit.

Standards language

IACS, volume resistivity or dielectric strength — pick the quantity the job uses.

Fire

Reaction to fire

Typical declared class: A2-s1,d0 typical; core A1. This is not a universal passport.

Resistance vs reaction

Euroclass is reaction. EI/R ratings are assemblies — boards, coats, cavities.

Melt-drip / char

Gypsum board tends to char or stay inorganic rather than melt-drip like commodity olefins.

Smoke / toxicity

CO, HCN, HF or fibres — the species depend on chemistry. Name the test (ISO 5659, EN 45545, NFPA 1971).

If a salesperson quotes a single “safety score”, ask which standard, which thickness, which year.

Keep exploring

More in Fire performance